Media Isolated Pressure Sensors |
|
ASCO pressure sensors provide accurate
measuring and linear electrical output signals for many process fluids.
The MEMs based sensor and one-piece pressure
cavity provides stable output measurements from 0 to 10,000
psi and supplies high sensitivity, low drift and highly
repeatable signaling. Electrical options include flying
leads, pins, spade terminals, or explosion-proof or
intrinsically safe versions. Mechanical options include
panel mounting, 316ss pressure vessel or Inconel with
process connections of 1/8-1/2 inch NPT, and other specialty
threading. Output signal options include 4-20m Amp or 1-5
Volt.
Pressure Sensors (PDF 2.5MB)
Installation & Maintenance
Manuals Available (Contact
Us)
CAD Drawings Available (Contact
Us)
Don't forget the
ASCO Standard Red Hat (HTML) |
|
 |
Series-40 Isolated Pressure Sensor
Series-42 Panel Mount Pressure Sensor
Series-43 Hazardous Location Sensor
Series-44 Intrinsically Safe Sensor
Series-46 Explosionproof Sensor
Series-47 High Accuracy Sensor
High Strength Stainless Steel Construction.
No silicone oil, no internal o-rings, no welds.
Wide operating temperature range.
Ranges up to 10,000 PSI.
Rugged design survives harsh environments.
Compatible with wide range of gases and liquids.
Suitable for high shock and vibration applications.
Panel up to .3" thick.
|
|
 |
Series-45 Tank Level Sensor
High Strength Stainless Steel Construction.
No silicone oil, no internal o-rings, no welds.
Wide operating temperature range.
Ranges up to 100 PSI.
Rugged design survives harsh environments.
Compatible with wide range of gases and liquids.
Suitable for high shock and vibration applications.
|
|
 |
Series-48 Combination Pressure/Temperature Sensor
High Strength Stainless Steel Construction.
No silicone oil, no internal o-rings, no welds.
Wide operating temperature range.
Ranges up to 1,000 PSI.
Low static & thermal errors.
Rugged design survives harsh environments.
Compatible with wide range of gases and liquids.
Suitable for high shock and vibration applications.
|
|
 |
Series-50 Wet/Wet Differential Pressure Transmitter
High Strength Stainless Steel Construction.
No internal o-rings.
Wide operating temperature range.
No internal fluid filled cavities.
EMI/RFI protection to 100V/m.
Low static & thermal errors.
Rugged design survives harsh environments.
Suitable for high shock and vibration applications.
|
|
Pressure &
Temperature Switches |
|
ASCO pressure and temperature switches
are a range of miniature to industrial size switches
designed to signal when process media reaches a set point of
pressure or temperature. The transducer will operate a
mechanical snap switch when the set point has been reached,
and will reset when the process media conditions drop below
the dead band. Options include fixed or adjustable dead band
and a a wide range of set points of vacuum to 8000 psi and
temperatures of -60ē to 640ēF (-51ē to
337ēC).
Pressure/Temperature Switches (PDF 1.6MB)
Installation & Maintenance
Manuals Available (Contact
Us)
CAD Drawings Available (Contact
Us)
Don't forget the
ASCO Standard Red Hat (HTML) |
|
 |
J-SERIES
Miniature Pressure Switches w/ Non-Adjustable Set Points
J-Series
miniature pressure switches have factory-set non-adjustable set
points and fixed deadband, with diaphragm/piston sensor. J-Series
switches are CSA approved and UL listed under "Industrial Control
Equipment". J-Series switches are sealed with specially compounded
epoxy that maintains its sealing integrity from -40 to 250°F. |
|
 |
H-SERIES Miniature Pressure Switches with Adjustable Set Points
H-Series miniature pressure
switches have field adjustable set points and fixed deadband,
with diaphragm/piston sensor. They are available in open frame
construction, Type 1 general purpose or Type 4 watertight enclosures. The
resilient diaphragm/piston construction helps provide long life and
maintains set point repeatability despite environmental temperature
variations. The full size electrical switch is a precision UL listed,
snap-action type. H-Series switches are CSA approved and are UL listed
under "Industrial Control Equipment". |
|
 |
P-SERIES Switches for Vacuum - 6000 psig with Open Frame, Type 1,4
Enclosures
P-Series pressure switches
consist of an open frame or enclosure protected switch unit and a
transducer unit. They can be ordered separately for customer stocking
and/or field assembly or as a complete factory-assembled unit.
Switches for Vacuum through 6000 psig with Adjustable Set Points and
Fixed or Adjustable Deadband. |
|
 |
S-SERIES Switches for Vacuum - 8000 psig, Differential or Level with
Type 1,4,7,9 Enclosures
S-Series pressure switches
consist of an open frame or enclosure protected switch unit and a
transducer unit. They can be ordered separately for customer stocking
and/or field assembly or as a complete factory-assembled unit.
Switches for Pressure to 8000 psig, Vacuum, Differential, or Level
Control with General Purpose, Watertight or Explosion-Proof Enclosures. |
|
 |
P-SERIES Switches for -60 through 510°F with Open Frame, Type 1,4
Enclosures
P-Series Temperature switches
consist of an open frame or enclosure protected switch unit and a
transducer unit. They can be ordered separately for customer stocking
and/or field assembly or as a complete factory-assembled unit. Switches for -30 through 510°F with Adjustable Set Points and Fixed or
Adjustable Deadband. |
|
 |
S-SERIES Switches for -60 through 640°F with Type 1,4,7,9 Enclosures
S-Series Temperature switches
consist of an open frame or enclosure protected switch unit and a
transducer unit. They can be ordered separately for customer stocking
and/or field assembly or as a complete factory-assembled unit. Switches for -30 through 640°F with Adjustable Set Points, Fixed or
Adjustable Deadband and General Purpose, Watertight or Explosion-Proof
Enclosures. |
|
 |
Marine Service Pressure Switches
These pressure switches are specially engineered for the harsh environment
of offshore applications. They are highly reliable and ideally suited for
use on platform panelboards, oil/gas wellheads and emergency shutdown
systems. |
|